STANDARDS
POLYGLAS
complies with the requirements and tolerance levels of :
1. The American Society For Testing & Material, ASTM
D-6223 Type I
or
Type
II*.
2.UEAtc (European Union of Technical Agreement).
3.MOAT 27-1983 and MOAT 30-1984.
4.CGSB (Canadian General Standards Board) 37-GP56M-July
1980.
INSTALLATION TOOLS REQUIRED
Gas torch, Knife, Trowel, Measuring tape, Marking string,
Gloves.
APPLICATION
POLYGLAS is installed by torch welding method, loose-laid or
fully bonded to substrate. When loose-laid, only laps are bonded
together. Peripheries and protrusions are sealed according to
specifications.
COVERAGE RATE
|
For
flat areas
|
1.13
M2/M2 per layer
|
|
For
30 cm. girth flashing
|
0.35
M2/Mt/ length
|
|
Average
wastage
|
3
- 5%
|
TORCHING
GUIDELINE
The
underside of the membrane should be torched just enough to
superficially melt the bitumen. Excessive heating may damage the
reinforcement. Overlaps should be re-heated from the top and
resealed with a trowel to ensure seam integrity.For details of
installation methods and flashing requirements, consult the
relevant BITUMAT Design and Installation Manual.
* On request product is available to meet the requirements.